Inspection Detail
Inspection: 114088065 - Del Zara Systems Inc. Dba Fanny'S Restaurant
Inspection Information - Office: Buffalo Area Office
Site Address:
Del Zara Systems Inc. Dba Fanny'S Restaurant
3500 Sheridan Drive
Amherst, NY 14226
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:5812
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/19/1995
Emphasis:
Case Closed: 11/08/1996
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 901215020 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 1 | 4 | |||
Current Violations | 1 | 2 | 3 | |||
Initial Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
Current Penalty | $375 | $0 | $0 | $0 | $0 | $375 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100106 E06 I | 10/16/1995 | 10/19/1995 | $1,250 | $1,250 | $0 | 11/07/1995 | J - ALJ Decision | Citation has been deleted. |
2. | 01002 | Serious | 19100157 G01 | 10/16/1995 | 11/20/1995 | $375 | $750 | $0 | 11/07/1995 | J - ALJ Decision | |
3. | 01003A | Other | 19101200 E01 | 10/16/1995 | 10/26/1995 | $0 | $1,000 | $0 | 11/07/1995 | J - ALJ Decision | |
4. | 01003B | Other | 19101200 G01 | 10/16/1995 | 10/26/1995 | $0 | $0 | $0 | 11/07/1995 | J - ALJ Decision | |
5. | 01003C | Other | 19101200 H01 | 10/16/1995 | 10/26/1995 | $0 | $0 | $0 | 11/07/1995 | J - ALJ Decision | |
6. | 02001 | Other | 19100106 E02 IVA | 10/16/1995 | 10/19/1995 | $0 | $0 | $0 | 11/07/1995 | J - ALJ Decision |
Investigation Summary
Employee #1 was filling an alcohol burner from a one gallon container. He placed the container on top of the counter and moved it down. When he then proceeded to light the burner, the flame flashed back to the container. Employee #1 attempted to snuff out the fire by covering the container opening. The can exploded, sending flaming alcohol around the room and injuring Employees #2 and #3. Powder from a fire extinguisher got in the eyes of Employee #4. All four employees were sent to the hospital, but only Employee #1 was seriously burned. The others were released after treatment.
Keywords: BURN, EYE, ALCOHOL, FLAMMABLE LIQUID, FIRE EXTINGUISHER, WORK RULES, FIRE, EXPLOSION, LEG
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 114088065 | Non Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
2 | 114088065 | Non Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
3 | 114088065 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
4 | 114088065 | Non Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |