Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1138546.015 - North Texas Heating And Air Conditioning, Inc.

Inspection Information - Office: Dallas Area Office

 

Inspection Nr: 1138546.015
Report ID: 0626300
Date Opened: 04/08/2016

Site Address:
North Texas Heating And Air Conditioning, Inc.
7000 Vassar Avenue
Dallas, TX 75205

Mailing Address:
Po Box 23, Argyle, TX 76226

Union Status: NonUnion

SIC:

NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors


Inspection Type: Fat/Cat

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/11/2016

Emphasis: L:Constr6

Case Closed: 05/31/2017


Related Activity
Type Activity Nr Safety Health
Accident 1079699
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 1 1 2
Initial Penalty $9,000 $0 $0 $2,000 $0 $11,000
Current Penalty $4,200 $0 $0 $996 $0 $5,196
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260416 A01 05/20/2016 05/26/2016 $4,200 $7,000 $0 I - Informal Settlement  
2. 01001B Serious 19261203 A 05/20/2016 05/26/2016 $0 $0 $0 I - Informal Settlement Citation has been deleted.
3. 01002 Other 19260501 B13 05/20/2016 05/26/2016 $996 $2,000 $0 I - Informal Settlement  
4. 02001 Other 19040039 A01 05/20/2016 $0 $2,000 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 84299.015
Event: 04/07/2016
Employee is electrocuted while installing return air plenum

At 3:50 p.m. on April 7, 2016, an employee was installing a return air plenum box in the attic of a residence. While manipulating the plenum box, measuring 12.5 inches by 24 inches by 24.5 inches, in an approximate 3 foot high crawl space of the attic, one of its sharp flanges sliced through an electrical cable that provided power to recessed lighting below. The energized cable carried 120 volts of electricity. As the lighting cable was contacted, the employee was electrocuted. The incident investigation revealed that no measures were in place to adequately protect the employee from electric shock hazards.

Keywords: Attic, Electric Cable, Electrical, Electrocuted, Guard, Lockout/Tagout

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1138546.015 35 M Fatality
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close