Inspection Detail
Inspection: 113546022 - Kaiser Systems, Inc.
Inspection Information - Office: Boston North Area Office
Site Address:
Kaiser Systems, Inc.
126 Sohier Road
Beverly, MA 01915
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3679
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/11/1999
Emphasis:
Case Closed: 10/12/1999
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 200772465 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $1,875 | $0 | $0 | $0 | $0 | $1,875 |
| Current Penalty | $937 | $0 | $0 | $0 | $0 | $937 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100333 A | 09/09/1999 | 10/12/1999 | $937 | $1,875 | $0 | I - Informal Settlement |
Investigation Summary
An employee was changing the power supply on a high-voltage burn-in station. An interface connector came loose exposing energized circuit parts. The employee contacted the energized parts with his hand and was electrocuted.
Keywords: E GI V, ELECTRICAL, ELECTROCUTED, UNGUARDED LIVE PARTS, ELEC CIRC PART--MISC, ELEC EQUIPMENT--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 113546022 | Hospitalized injury | Electric Shock | Occupation not reported |
Translate