Inspection Detail
Inspection: 1131096.015 - 69962 - Wood Connection Inc
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
69962 - Wood Connection Inc
600 Greenlawn Drive
Columbia, SC 29209
Mailing Address:
4216 Nord Lane, Duluth, GA 30096
Union Status: NonUnion
SIC:1761
NAICS: 238170/Siding Contractors
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/21/2016
Emphasis:
Case Closed: 02/01/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1070021 | ||
| Inspection | 1175886 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
| Current Penalty | $2,000 | $0 | $0 | $0 | $0 | $2,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260451 F06 | 07/07/2016 | 07/11/2016 | $0 | $2,000 | $0 | Z - Issued | Citation has been deleted. | |
| 2. | 01002 | Serious | 19260454 A | 07/07/2016 | 08/09/2016 | $0 | $1,000 | $0 | Z - Issued | Citation has been deleted. | |
| 3. | 01003A | Serious | 19260451 F06 | 07/07/2016 | 07/11/2016 | $2,000 | $2,000 | $0 | Z - Issued | ||
| 4. | 01003B | Serious | 19260454 A | 07/07/2016 | 08/09/2016 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At approximately 1:35 p.m. on March 8, 2016, Employees #1 and #2 were on the ground level of the north side of a three story apartment building number 1. Both employees were getting ready to set a 41-ft 8-in. long aluminum scaffold pole up right for a scaffold set up. A coworker was on the roof area of building number 1 with a rope to pull the scaffold pole up right. The pole was mostly upright, when a strong breeze blew the scaffold pole towards a 13,800 volt single phase power line. Employee #1 and Employee #2 were holding scaffold pole when it made contact with the power line. Employee #1 died on site. Employee #2 received third degree burns and was transported to a burn center. Primary phase of power line above the ground level was 38-ft high. The distance from scaffold pole, when it was upright, to primary phase was 28-ft. The amperage of power line with no load was 0. The fault amperage current when scaffold pole made contact with power line was 2,558 amps. The neutral line was 31-ft 5-in. above ground level.
Keywords: Burn, Electric Shock, Electrocuted, Power Lines, Scaffold
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1131096.015 | 55 | M | Fatality | Occupation not reported | |
| 2 | 1131096.015 | 55 | M | Hospitalized injury | Occupation not reported |