Inspection Detail
Inspection: 112873930 - J T & T Air Conditioning Corp
Inspection Information - Office: Long Island Area Office
Site Address:
J T & T Air Conditioning Corp
1650 New York Ave
Huntington Station, NY 11746
Mailing Address:
65-21 Grand Ave, Maspeth, NY 11378
Union Status: NonUnion
SIC:1711
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/23/1996
Emphasis:
Case Closed: 02/16/1996
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361114812 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $1,500 | $0 | $1,500 |
Current Penalty | $0 | $0 | $0 | $1,050 | $0 | $1,050 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 19040008 | 01/25/1996 | 01/30/1996 | $1,050 | $1,500 | $0 | I - Informal Settlement |
Investigation Summary
An employee was using a Lincoln ac/dc, constant-current electric arc welder (Model No. AC/DC 225/125). The switch on the welder was in the 135-ampere, ac position. (A label on the welder warned against using it with damp clothing.) The employee, who was lying on a metal duct and who was drenched in his own sweat, was welding in tight quarters. He was electrocuted. The medical examiner's electrical expert reported that 83 volts was available at the welding electrode. The welding equipment was found to be in excellent condition.
Keywords: E GI III, ELECTRICAL, ELECTROCUTED, WELDER, WELDING, WET OPERATION, WELDING ELECTRODE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 112873930 | Fatality | Electric Shock | Occupation not reported |