Powered by GoogleTranslate

Inspection Detail

Inspection: 1128560 - E S P Concrete Pumping Inc

Inspection Information - Office: Wilkes Barre Area Office

 

Inspection Nr: 1128560
Report ID: 0317700
Date Opened: 07/23/1991

Site Address:
E S P Concrete Pumping Inc
Vocational Ed. Hs 2990 W. 4th St.
Williamsport, PA 17701

Mailing Address:
Rr Box 310, Sweet Valley, PA 18656

Union Status: NonUnion

SIC:1611

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/12/1991

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 11/03/1991


Related Activity
Type Activity Nr Safety Health
Accident 360670335
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 4 1 5
Initial Penalty $2,850 $0 $0 $300 $0 $3,150
Current Penalty $2,250 $0 $0 $100 $0 $2,350
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260550 A15 I 09/24/1991 09/29/1991 $1,200 $1,500 $0 I - Informal Settlement  
2. 01001B Serious 19260020 B01 09/24/1991 10/29/1991 $0 $0 $0 I - Informal Settlement  
3. 01001C Serious 19260021 B02 09/24/1991 10/29/1991 $0 $0 $0 I - Informal Settlement  
4. 01002 Serious 19260059 E01 09/24/1991 10/29/1991 $350 $450 $0 I - Informal Settlement  
5. 01003 Serious 19260059 G01 09/24/1991 10/29/1991 $350 $450 $0 I - Informal Settlement  
6. 01004 Serious 19260059 H 09/24/1991 10/29/1991 $350 $450 $0 I - Informal Settlement  
7. 02001 Other 19030002 A01 09/24/1991 10/29/1991 $100 $300 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14543516
Event: 07/23/1991
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

A CONCRETE PUMPER TRUCK WAS BEING USED TO FILL CONCRETE FORMS. THE BOOM FROM THE PUMPER CONTACTED AN OVERHEAD POWER LINE AS THE FORMS WERE BEING FILLED BY THE PUMPER'S HOSE. AN EMPLOYEE HOLDING THE HOSE WAS ELECTROCUTED.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, CONCRETE TRUCK, E C, TRUCK BOOM, BOOM, ELECTROCUTED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1128560 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.