Inspection Detail
Inspection: 112409628 - Wiliam A. Hazel Inc.
Inspection Information - Office: Va-E-Manassas (Regional Office)- Safety 0355114
Site Address:
Wiliam A. Hazel Inc.
8230 Unton Hall Road
Gainsville, VA 22065
Mailing Address:
4305 Hazel Park Court, Chantilly, VA 22021
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/22/1992
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 09/19/1994
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360301337 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $15,000 | $0 | $0 | $0 | $0 | $15,000 |
| Current Penalty | $3,750 | $0 | $0 | $0 | $0 | $3,750 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | ELEC040802 | 02/16/1993 | 02/22/1993 | $1,875 | $3,750 | $0 | 02/23/1993 | Y - State Decision | |
| 2. | 01002 | Other | ELEC0409 A01 | 02/16/1993 | 02/22/1993 | $0 | $3,750 | $0 | 02/23/1993 | Y - State Decision | |
| 3. | 01003A | Serious | ELEC0409 B | 02/16/1993 | 02/22/1993 | $3,750 | $3,750 | $0 | 02/23/1993 | Y - State Decision | Citation has been deleted. |
| 4. | 01003B | Serious | 19260020 B02 | 02/22/1993 | 02/22/1993 | $0 | $0 | $0 | 02/23/1993 | Y - State Decision | Citation has been deleted. |
| 5. | 01004 | Serious | ELEC0410 | 02/16/1993 | 02/22/1993 | $1,875 | $3,750 | $0 | 02/23/1993 | Y - State Decision |
Investigation Summary
AN EMPLOYEE WAS POSITIONING A MOBILE DRILLING RIG FOR A BLASTING CREW. THE EMPLOYEE WAS STANDING ON THE GROUND WHILE HE WAS OPERATING THE CONTROLS FOR THE BOOM. THE BOOM ON THE RIG CONTACTED A 17.5-KILOVOLT OVERHEAD POWER LINE, AND THE EMPLOYEE RECEIVED AN ELECTRIC SHOCK. HE WAS HOSPITALIZED FOR HIS INJURIES.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, E GI IA, DRILL RIG--NON-OIL, ELECTRIC SHOCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 112409628 | Hospitalized injury | Electric Shock | Drillers, earth |
Translate