Inspection Detail
Inspection: 112216221 - Stream Energy Inc.
Inspection Information - Office: Labor Enforcement Task Force (Letf) Unit - South
Site Address:
Stream Energy Inc.
Perkins Rd.
New Cuyama, CA 93254
Mailing Address:
P.O. Box 179, Cuyama, CA 93254
Union Status: NonUnion
SIC:1311
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/08/1990
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 07/27/1995
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361294440 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 2 | 3 | |||
Current Violations | 1 | 2 | 3 | |||
Initial Penalty | $1,400 | $0 | $0 | $0 | $0 | $1,400 |
Current Penalty | $1,400 | $0 | $0 | $0 | $0 | $1,400 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 6772 C | 11/16/1990 | 12/21/1990 | $0 | $0 | $0 | - | ||
2. | 01002 | Other | 6773 C | 11/16/1990 | 12/21/1990 | $0 | $0 | $0 | - | ||
3. | 02001 | Serious | 6777 D | 11/16/1990 | 11/08/1990 | $1,400 | $1,400 | $0 | - |
Investigation Summary
At 7:39 p.m. on November 6, 1990, Employee #1, a petroleum worker, attempted to relight the reboiler inside the plant complex. A flash explosion occurred, and he suffered second- and third-degree burns on his face and hands. He was transported to Marian Hospital in Santa Maria, CA, then flown to Sherman Oaks Burn Center in Van Nuys. The plant foreman stated that dry gas leaking into the reboiler may have caused the boiler to explode. Electronic ignition was to be installed so that the reboiler would not need to be lit manually. The employer was cited for a general violation of T8CCR 6772 (c) and 6773 (c) for petroleum safety, and a serious violation of T8CCR 6777 (d).
Keywords: BURN, LEAK, FLAMMABLE VAPORS, WORK RULES, BOILER, OIL WELL DRILLING, CONSTRUCTION, EXPLOSION, FACE, HAND
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 112216221 | Hospitalized injury | Burn/Scald(Heat) | Petroleum engineers |