Inspection Detail
Inspection: 112197447 - J.A. Bozung
Inspection Information - Office: Monrovia District Office
Site Address:
J.A. Bozung
9401 Whitmore
El Monte, CA 91731
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3312
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/23/1991
Emphasis:
Case Closed: 10/22/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361279219 |
Investigation Summary
A WELDER BEGAN WORKING WITH AN AIRCO HELIWELDER (MODEL NO. 3AIDDTNA224HPAIB-A-SCMIS, SERIAL NO. R372356). WHEN THE EMPLOYEE TOUCHED THE WELDING LEAD, HE RECEIVED A VERY SEVERE ELECTRIC SHOCK, WHICH CAUSED INTERNAL INJURIES. HE FELT NAUSEOUS. HE HAD SEIZURES AND STOPPED BREATHING. CARDIO-PULMONARY RESUSCITATION WAS APPLIED BY A COWORKER. EMERGENCY RESCUE SERVICES TRANSPORTED HIM TO A HOSPITAL, WHERE HE WAS TREATED FOR MORE THAN 24 HOURS. INVESTIGATION REVEALED THAT THE EMPLOYER DID NOT MAINTAIN THE WELDING MACHINE IN A SAFE CONDITION.
Keywords: E GI III, ELECTRICAL, CPR, WELDER, WELDING, WELDING CABLE, ELECTRIC SHOCK, WELDING ELECTRODE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 112197447 | Hospitalized injury | Electric Shock | Welders and cutters |
Translate