Inspection Detail
Inspection: 112104724 - Maxwell Laboratories
Inspection Information - Office: San Diego District Office
Site Address:
Maxwell Laboratories
8888 Balboa Ave.
San Diego, CA 92123
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3399
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/11/1992
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 03/31/1994
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361367576 |
Investigation Summary
An employee was performing a test on a capacitor. The meter had not been isolated in accordance with the employer's engineering department's recommendations. The test instrument he was using failed, burning the employee. He was hospitalized for his injuries.
Keywords: BURN, E GI II, ELECTRIC ARC, ELECTRICAL, ELECTRICAL TESTING, TEST EQUIPMENT, ELECTRICAL FAULT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 112104724 | Hospitalized injury | Burn(Chemical) | Electronic repairers, communica. & indus. equip. |
Translate