Inspection Detail
Inspection: 112088471 - Rust Scaffold Rental & Erection
Inspection Information - Office: Long Beach District Office
Site Address:
Rust Scaffold Rental & Erection
3700 W 190th St
Torrance, CA 90509
Mailing Address:
1300 S Atlantic Ave, Compton, CA 90221
Union Status: Union
SIC:2911
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/04/1992
Emphasis:
Case Closed: 03/03/1994
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361325277 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 2 | 5 | |||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $2,250 | $0 | $0 | $0 | $0 | $2,250 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 5194 H02 F | 05/04/1992 | 06/04/1992 | $0 | $0 | $0 | 06/26/1992 | J - ALJ Decision | Citation has been deleted. |
| 2. | 01002 | Other | 5167 A | 05/04/1992 | 06/04/1992 | $0 | $0 | $0 | 06/26/1992 | J - ALJ Decision | Citation has been deleted. |
| 3. | 02001 | Other | 5144 A | 05/04/1992 | 06/04/1992 | $0 | $750 | $0 | 06/26/1992 | J - ALJ Decision | |
| 4. | 03001 | Serious | 6815 A | 05/04/1992 | 05/18/1992 | $750 | $750 | $0 | 06/26/1992 | J - ALJ Decision | Citation has been deleted. |
| 5. | 04001 | Serious | 6786 A | 05/04/1992 | 05/18/1992 | $750 | $750 | $0 | 06/26/1992 | J - ALJ Decision | Citation has been deleted. |
Investigation Summary
On November 3, 1991, I.S.T. Mechanical was removing a blind from a 10 in. flange on the line from the depropanizer overhead condensers (8-E-35 A/B) to the depropanizer overhead receiver (8-C-13) under fresh air. The flange was parted and some vapors escaped. The flange was closed and the decision was made to connect a water hose to a 3/4 in. bleeder valve located upstream from the flange and put a water seal in the piping between the flange and the receiver. Employees were setting the gasket when the water seal was lost and a hydrocarbon cloud was released. Paramedics and emergency crews of Mobil Oil Corp. responded to the accident and treated I.S.T. employees. Employees #1 through #3 were brought to Little Company of Mary in Torrance, CA, and treated for chemical burns of the feet and inhalation of vapors.
Keywords: LEAK, REPAIR, VAPOR, GASKET, INHALATION, CHEMICAL BURN, FOOT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 112088471 | Hospitalized injury | Burn(Chemical) | Occupation not reported | ||
| 2 | 112088471 | Hospitalized injury | Asphyxia | Occupation not reported | ||
| 3 | 112088471 | Hospitalized injury | Asphyxia | Occupation not reported |