Powered by GoogleTranslate

Inspection Detail

Inspection: 112087713 - Pacific Optical

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 112087713
Report ID: 0950635
Date Opened: 04/28/1992

Site Address:
Pacific Optical
2660 Columbia
Torrance, CA 90505

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3827

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/07/1992

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/15/1992


Related Activity
Type Activity Nr Safety Health
Referral 901645564 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 5
Current Violations 3 2 5
Initial Penalty $1,350 $0 $0 $0 $0 $1,350
Current Penalty $1,350 $0 $0 $0 $0 $1,350
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 05/07/1992 06/07/1992 $0 $0 $0 -  
2. 01002 Other 3216 B 05/07/1992 06/07/1992 $0 $0 $0 -  
3. 02001 Serious 2717 05/07/1992 05/21/1992 $900 $900 $0 -  
4. 03001 Serious 29400002 A 05/07/1992 05/21/1992 $0 $0 $0 -  
5. 04001 Serious 23400017 A 05/07/1992 05/21/1992 $450 $450 $0 -  

Investigation Summary

Investigation Nr: 170187660
Event: 05/27/1992
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

AN EMPLOYEE WAS WORKING BENEATH THE COATING CHAMBER OF A COATING MACHINE, ADJUSTING THE MONITORS. HE APPARENTLY CONTACTED UNGUARDED 6000-VOLT CONDUCTORS THAT WERE LOCATED ADJACENT TO THE MONITORS. THE EMPLOYEE RECEIVED AN ELECTRIC SHOCK, A BURN, AND CUTS. HE WAS HOSPITALIZED FOR HIS INJURIES.

Keywords: BURN, E GI IV, ELECTRICAL, LOCKOUT, UNGUARDED LIVE PARTS, LACERATION, ELEC CIRC PART--MISC, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112087713 Hospitalized injury Electric Shock Industrial engineering technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close