Powered by GoogleTranslate

Inspection Detail

Inspection: 112087374 - Douglas Aircraft Co

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 112087374
Report ID: 0950635
Date Opened: 03/29/1991

Site Address:
Douglas Aircraft Co
19503 Normandie
Torrance, CA 90502

Mailing Address:
21000 Normandie, Torrance, CA 90502

Union Status: Union

SIC:3721

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 06/14/1991

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 02/03/1994


Related Activity
Type Activity Nr Safety Health
Referral 901646448 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $2,120 $0 $0 $0 $0 $2,120
Current Penalty $4,240 $0 $0 $0 $0 $4,240
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5143 A15 06/14/1991 06/21/1991 $0 $0 $0 -  
2. 02001 Serious 51540001 B 06/14/1991 06/21/1991 $2,120 $1,060 $0 P - Petition to Mod Abatement  
3. 03001 Serious 5143 A01 06/14/1991 06/21/1991 $2,120 $1,060 $0 P - Petition to Mod Abatement  

Investigation Summary

Investigation Nr: 170186944
Event: 03/29/1991
Employee exposed to trichloroethane vapors

At approximately 11:25 p.m. on February 19, 1991, degreaser bath #150 (Department 402, Building 6) released trichloroethane vapors and the building was evacuated. Employee #1, a sheet metal worker, was overcome by the fumes and was transported to General Harbor Medical Center complaining of shortness of breath and dizziness. Upon investigation, it was determined that one of the magnetic safety valves that controlled the level of steam heat had failed to close. In addition, the force draft blower and chill water circulating the trichloroethane was inoperative. It was concluded that the lack of cooling capacity coupled with failure of the magnetic safety valve allowed the release of trichloroethane vapors.

Keywords: TRICHLOROETHANE, MAINTENANCE, SAFETY RELIEF VALVE, WORK RULES, INHALATION, DIZZINESS, CHEMICAL VAPOR, TOXIC FUMES, ACCIDENTAL DISCHARGE, MECH MALFUNCTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112087374 Hospitalized injury Other Sheet metal workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close