Inspection Detail
Inspection: 112072657 - Agrashell
Inspection Information - Office: Long Beach District Office
Site Address:
Agrashell
4560 26th St.
Vernon, CA 90058
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2048
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/08/1993
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 06/22/1995
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362165235 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $1,750 | $0 | $0 | $0 | $0 | $1,750 |
| Current Penalty | $1,750 | $0 | $0 | $0 | $0 | $1,750 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 25400003 B | 02/08/1993 | 02/25/1993 | $1,750 | $1,750 | $0 | - |
Investigation Summary
Two employees of a company that grinds nutshells into abrasive products were working in a mill room in the plant. They smelled smoke coming from the second or third catwalk levels above the mills. Both of them went to the third level to take a look. One of them (employee #2) noticed cinders around a conveyor motor on the second level. He went to scoop the cinders with a steel plate. The cinders ignited in a flash. The employee dropped the steel plate with the cinders and a second ignition took place. The other employee, who was still on the third level, jumped down to the second level, a distance of 8 feet. Both employees then evacuated the area and shut down the mill. Employee #1 suffered sprains in his foot, knee, and shoulder. Employee #2 suffered first and second degree burns on his face and on one of his arms. The fire appeared to have been caused by the use of unapproved electric equipment in a Class II, Division 2 hazardous location.
Keywords: BURN, E GI V, DUST, ELECTRICAL, FIRE, FALL, EQUIPMENT APPROVAL, SPRAIN, ELEC EQUIPMENT--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 112072657 | Non Hospitalized injury | Burn/Scald(Heat) | Machine operators, not specified | ||
| 2 | 112072657 | Non Hospitalized injury | Strain/Sprain | Machine operators, not specified |
Translate