Powered by GoogleTranslate

Inspection Detail

Inspection: 112071030 - Dianas Mexican Food Products Inc

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 112071030
Report ID: 0950642
Date Opened: 12/19/1991

Site Address:
Dianas Mexican Food Products Inc
16330 S Pioneer Bl
Norwalk, CA 90650

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2099

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/04/1992

Emphasis:

Case Closed: 12/19/1992


Related Activity
Type Activity Nr Safety Health
Accident 361326630
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 5 7
Current Violations 2 5 7
Initial Penalty $2,500 $0 $0 $250 $0 $2,750
Current Penalty $2,500 $0 $0 $250 $0 $2,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A07 A 02/04/1992 12/19/1991 $0 $0 $0 -  
2. 01002 Other 3664 A 02/04/1992 02/14/1992 $0 $0 $0 -  
3. 01003 Other 342 A 02/04/1992 12/19/1992 $0 $0 $0 -  
4. 01004 Other 461 C 02/04/1992 02/28/1992 $250 $250 $0 -  
5. 01005 Other 14301 A02 02/04/1992 02/04/1992 $0 $0 $0 -  
6. 02001 Serious 4070 A 02/04/1992 02/11/1992 $500 $500 $0 -  
7. 03001 Serious 4542 C01 02/04/1992 12/19/1991 $2,000 $2,000 $0 -  

Investigation Summary

Investigation Nr: 956045
Event: 12/17/1991
Employee's fingers amputated by dough mixer

At approximately 4:00 p.m. on December 17, 1991, Employee #1 was removing dough from a horizontal, tilted mixer equipped with an electrical inch device. With the mixer open, Employee #1 pushed the single inch button, while simultaneously his right hand reached into the mixer. The mixer turned, amputating Employee #1's thumb, index, middle, and ring fingers. Employee #1 was hospitalized. No name plate was found on the mixer. A violation of T8CCR 4542(c)(1), serious, was observed. Non-accident related violations, serious, general, and regulatory, were also found and cited.

Keywords: ROTATING PARTS, AMPUTATED, FINGER, WORK RULES, MIXER, CAUGHT BY, THUMB, LOCKOUT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112071030 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close