Inspection Detail
Inspection: 112068242 - Wilcox Machine
Inspection Information - Office: Riverside District Office
Site Address:
Wilcox Machine
7180 Scout Ave
Bell Gardens, CA 90201
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3599
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/19/1991
Emphasis:
Case Closed: 12/11/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361340920 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 23400001 | 11/22/1991 | 11/22/1991 | $0 | $0 | $0 | - | ||
| 2. | 01002 | Other | 23400001 | 11/22/1991 | 11/27/1991 | $0 | $0 | $0 | - | ||
| 3. | 01003 | Other | 342 A | 11/22/1991 | 11/22/1991 | $0 | $0 | $0 | - |
Investigation Summary
AN EMPLOYEE CLOSED A SWITCH TO RUN A POSITIONER FOR WELDING OPERATIONS. THE SWITCH CONTROLLED ELECTRIC POWER TO A NEARBY RECEPTACLE OUTLET USED TO CONNECT A WELDER OR THE POSITIONER. AS THE EMPLOYEE WAS OPERATING ITS HANDLE, IT BROKE OFF AS SOON AS THE SWITCH WAS PARTIALLY CLOSED. AFTER HE DID THIS, THE POSITIONER WAS WORKING; HOWEVER, THE EMPLOYEE RETURNED TO THE FRONT OF THE SWITCH TO SEE WHY THE HANDLE BROKE. APPARENTLY, THE COVER ON THE SWITCH, WHICH WAS A TYPE THAT HAS SLIDING CONTACTS, WAS NOT PROPERLY SNAPPED INTO PLACE; AND, SINCE THE TURNING MECHANISM WOULD BE OUT OF ALIGNMENT, THE SWITCH WOULD NOT CLOSE FULLY. IN THE MEANTIME, THE COVER OF THE SWITCH SLID DOWN AND CONTACTED THE HALF-CLOSED BLADES ON THE THREE POLES OF THE SWITCH (THE THREE POINTS OF CONTACT WERE QUITE EVIDENT ON THE SWITCH COVER). THE METAL COVER'S CONTACTING THE ENERGIZED PARTS OF THE SWITCH CAUSED AN ELECTRICAL FAULT. THE ENSUING ELECTRIC ARC BURNED THE EMPLOYEE, WHO WAS STANDING IN FRONT OF THE SWITCH. THE EMPLOYEE WAS HOSPITALIZED FOR HIS INJURY. THE CAUSE OF THE LOOSENESS OF THE COVER COULD NOT BE DETERMINED.
Keywords: BURN, E GI V, ELECTRIC ARC, ELECTRICAL, ELECTRIC SWITCH, ELECTRICAL FAULT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 112068242 | Hospitalized injury | Burn/Scald(Heat) | Welders and cutters |
Translate