Inspection: 112052766 - Tom Rogers Firewood

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 112052766
Report ID: 0950631
Date Opened: 03/19/1992

Site Address:
Tom Rogers Firewood
Sand Canyon Rd
Irvine, CA 92714

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2499

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/26/1992

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/26/1994


Related Activity
Type Activity Nr Safety Health
Accident 361326176
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $1,200 $0 $0 $0 $0 $1,200
Current Penalty $1,200 $0 $0 $0 $0 $1,200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 07/21/1992 08/23/1992 $0 $0 $0 -  
2. 01002 Other 342 A 07/21/1992 07/21/1992 $0 $0 $0 -  
3. 02001 Serious 4185 07/21/1992 08/23/1992 $1,200 $1,200 $0 -  

Investigation Summary

Investigation Nr: 170164727
Event: 11/27/1991
Employee's finger tip amputated by wood splitter

At about 2:00 p.m. on November 27, 1991, Employee #1, of Tom Rogers Firewood, was operating a wood splitter machine splitting a piece of eucalyptus wood about 2 ft in diameter and 2 ft high, which had cracks on its side. The employee had his hand on the side of the wood and when the splitter started to cut through the wood, a crack closed, catching the tip of his finger. The splitter amputated the tip of his right forefinger. He was transported by the paramedics to Irvine Medical Center for treatment. The splitter is similar to a press brake; its power is derived from a diesel engine which drives the hydraulic pump. The unit is actuated by a lever which requires constant pressure by one hand; the splitter would stop when the lever was released. The size of the wood does not require the operator's hand to be placed in the point of operation. The blade has to travel only halfway through the wood to split it. The operator was trained by the employer and was qualified to operate the splitter. A serious violation was cited for failure to guard the point of operation.

Keywords: AMPUTATED, FINGER, WORK RULES, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112052766 Non Hospitalized injury Amputation Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.