Inspection Detail
Inspection: 112040340 - Ameron, Concrete And Steel Pipe Group
Inspection Information - Office: San Bernardino District Office
Site Address:
Ameron, Concrete And Steel Pipe Group
12455 Arrow Route
Etiwanda, CA 91739
Mailing Address:
, , 00000
Union Status: Union
SIC:3547
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/05/1991
Emphasis:
Case Closed: 03/18/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361266828 |
Investigation Summary
At approximately 12:30 p.m. on February 13 1991, Employee #1 was repairing a ring-type header device used in the manufacture of large diameter steel pipe. The header was on the ground near the path of a wheel-mounted mobile crane. The crane operator misjudged the clearance between the header and the crane, and struck the header. The dislodged header struck Employee #1 on his left foot. He sustained injuries that required hospitalization.
Keywords: CLEARANCE, REPAIR, STRUCK AGAINST, STRUCK BY, CRANE OPERATOR, FOOT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 112040340 | Hospitalized injury | Fracture | Boilermakers |