Inspection Detail
Inspection: 112017975 - Styrotek, Inc.
Inspection Information - Office: Fresno District Office
Site Address:
Styrotek, Inc.
545 Road 176
Delano, CA 93215
Mailing Address:
P O Box 1180, Delano, CA 93215
Union Status: NonUnion
SIC:5085
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/29/1998
Emphasis:
Case Closed: 09/23/1998
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362282873 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $300 | $0 | $300 |
| Current Penalty | $0 | $0 | $0 | $300 | $0 | $300 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3310 A | 09/03/1998 | 09/07/1998 | $300 | $300 | $0 | - |
Investigation Summary
At approximately 6:45 a.m. on March 20, 1998, Employee #1 and a coworker, of Styrotek, Inc., were operating a control panel adjacent to a water pit. Hot water splashed out of a vent onto Employee #1, who suffered second- and third-degree burns on his back. He was taken to Delano Hospital and then transferred to the Sherman Oaks (CA) Burn Center for further treatment.
Keywords: BURN, BACK, PIT, SPILL, ACCIDENTAL DISCHARGE, HIGH TEMPERATURE, HOT WATER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 112017975 | Hospitalized injury | Burn/Scald(Heat) | Machine operators, not specified |