Inspection Detail
Inspection: 112004759 - Tanimura & Antle
Inspection Information - Office: San Diego District Office
Site Address:
Tanimura & Antle
Parkman Rd & Perez Rd
Bard, CA 92222
Mailing Address:
Po Box 4070, Salinas, CA 93912
Union Status: NonUnion
SIC:0722
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/21/1991
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/10/1991
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361305808 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 5045 D03 | 03/01/1991 | 03/01/1991 | $0 | $0 | $0 | - | ||
2. | 01002 | Other | 14305 D01 | 03/01/1991 | 03/01/1991 | $0 | $0 | $0 | - |
Investigation Summary
A 43-year-old farm worker was tying down a load of cauliflower on a trailer hitched to his tractor. When he tossed a 9.8-meter-long, 6-millimeter-diameter tie-down cable over the 4.3-meter-tall load of boxes on the trailer, the end of the cable contacted a 17-kilovolt overhead power line located 8.5 meters above the trailer. The employee received an electric shock and was knocked unconscious. A witness reported the accident, and emergency medical services were summoned. The superintendent arrived in 3 minutes, picked up the worker, carried him 10 to 12 meters back into the field and administered cardio-pulmonary resuscitation. The emergency medical services unit arrived about 20 minutes later and transported the injured employee to a hospital, where he was held for treatment. The electric current had amputated three fingers from his left hand.
Keywords: BURN, AMPUTATED, OVERHEAD POWER LINE, ELECTRICAL, WIRE ROPE, CPR, AGRICULTURE, FINGER, ELECTRIC SHOCK, E AG
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 112004759 | Hospitalized injury | Electric Shock | Farm workers |