Inspection Detail
Inspection: 111979266 - Orange County Register (Print Shop)
Inspection Information - Office: Santa Ana District Office
Site Address:
Orange County Register (Print Shop)
1701 S Lewis St
Anaheim, CA 92815
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2711
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/05/1996
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 01/02/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362224289 | ||
| Accident | 362224321 |
Investigation Summary
A production maintenance worker and his supervisor had just replaced an ultraviolet light at a conveyor. The circuit for the light was deenergized. The supervisor had to leave for a short period and instructed the maintenance worker to wait until he returned and not to touch anything. The maintenance worker then turned around to check the circuit supplying the light he had just replaced. As he was bending down, his knee contacted an energized circuit directly below the one he was checking. He received an electric shock and third-degree burns to his left knee. He was hospitalized for his injuries.
Keywords: BURN, ELEC PROTECT EQUIP, E GI IV, ELECTRICAL, ELECTRICAL WORK, LOCKOUT, ELEC CIRC PART--MISC, ELECTRIC SHOCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111979266 | Hospitalized injury | Electric Shock | Not specified mechanics and repairers |