Powered by GoogleTranslate

Inspection Detail

Inspection: 111978052 - Kirkhill Rubber Co

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 111978052
Report ID: 0950631
Date Opened: 03/15/1991

Site Address:
Kirkhill Rubber Co
300 E Cypress
Brea, CA 92621

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3069

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/22/1991

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/22/1991


Related Activity
Type Activity Nr Safety Health
Accident 361264831
Accident 361264872
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $2,000 $0 $0 $0 $0 $2,000
Current Penalty $2,000 $0 $0 $0 $0 $2,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5044 C02 03/29/1991 04/19/1991 $0 $0 $0 -  
2. 01002 Other 5043 03/29/1991 03/22/1991 $0 $0 $0 -  
3. 02001 Serious 5044 E 03/29/1991 03/22/1991 $2,000 $2,000 $0 -  

Investigation Summary

Investigation Nr: 170166540
Event: 03/12/1991
Employee injured when struck by chain that broke

At approximately 12:40 p.m. on March 12, 1991, Employee #1 and two coworkers, of Kirkhill Rubber Co., were repositioning the drive gear of a 72 in. rubber mill into a shaft. They used a 3/8 in. chain-link sling that was wrapped around the gear housing and a 60-ton hydraulic jack positioned horizontally to apply pressure on the gear on one end, while the other end of the jack was on the chain. Employee #1 was heating the gear with a welding torch so it would expand and fit. While the gear was being heated, a coworker was pumping on the hydraulic jack. The chain broke at a connecting link and the loose end of the chain struck Employee #1 on the chest. He was transported by paramedics to UC-Irvine Medical Center, where he was hospitalized. The primary causal factor of this accident was the chain being subjected to a load in excess of its rated capacity. To prevent a recurrence of this accident, the employer agreed to mark all slings with their maximum rated capacity and not subject them to excessive loads. Employees will also be trained in the safe use of slings.

Keywords: CHAIN, CHEST, WORK RULES, OVERLOADED, EQUIPMENT FAILURE, STRUCK BY, SLING, UNTRAINED, BROKEN CHAIN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111978052 Hospitalized injury Fracture Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.