Powered by GoogleTranslate

Inspection Detail

Inspection: 111971263 - Thomas Betts Corp.

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 111971263
Report ID: 0950631
Date Opened: 09/04/1990

Site Address:
Thomas Betts Corp.
76 Fairbanks
Irvine, CA 92718

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3672

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/06/1990

Emphasis:

Case Closed: 12/11/1990


Related Activity
Type Activity Nr Safety Health
Accident 361053093
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3328 E 10/19/1990 10/19/1990 $0 $0 $0 A - Amendment  
2. 01002 Other 4208 A 10/19/1990 11/19/1990 $0 $0 $0 A - Amendment  
3. 01003 Other 4193 E 10/19/1990 10/19/1990 $0 $0 $0 A - Amendment  
4. 01004 Other 4310 A 10/19/1990 10/25/1990 $0 $0 $0 A - Amendment  
5. 01005 Other 3576 A 10/19/1990 10/19/1990 $0 $0 $0 A - Amendment  

Investigation Summary

Investigation Nr: 170164602
Event: 07/16/1990
Employee's fingertip avulsed by pneumatic clamp

Employee #1, a manufacturing engineer, was clearing a jam on the assembly line that automatically inserted and bent pins on computer connectors. Electrical power to the unit was shut off. Employee #1 inadvertently leaned against the emergency STOP button, releasing residual air into the system that controlled the pneumatic clamp. His fingertip was avulsed by the clamp. The pneumatic system lacked a dump valve to prevent the build-up of residual air. At the time of the inspection, an air dump valve had already been installed. The assembly machine had adequate guarding (a light curtain) for normal operating hazards.

Keywords: AIR PRESSURE, FINGER, EMERGENCY STOP, JAMMED, LACERATION, VALVE, PRESSURE RELEASE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111971263 Non Hospitalized injury Cut/Laceration Production inspectors, checkers and examiners
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close