Inspection Detail
Inspection: 111968376 - Sunsweet Growers Inc
Inspection Information - Office: Redding District Office
Site Address:
Sunsweet Growers Inc
901 N. Walton
Yuba City, CA 95991
Mailing Address:
P. O. Box 232, Yuba City, CA 95992
Union Status: Union
SIC:2034
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/09/1994
Emphasis:
Case Closed: 02/14/1995
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362111387 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 1 | 3 | |||
Initial Penalty | $6,125 | $0 | $0 | $300 | $0 | $6,425 |
Current Penalty | $6,125 | $0 | $0 | $300 | $0 | $6,425 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3308 | 12/13/1994 | 08/23/1994 | $300 | $300 | $0 | - | ||
2. | 02001 | Serious | 3300 B | 12/13/1994 | 08/09/1994 | $1,125 | $1,125 | $0 | - | ||
3. | 03001 | Serious | 3300 A | 12/13/1994 | 08/09/1994 | $5,000 | $5,000 | $0 | - |
Investigation Summary
At 9:50 a.m. on August 7, 1994, Employee #1, of Sunsweet Growers, Inc., was working at the prune prep area. He was turning on a steam valve when the valve broke, spraying him with steam. At the same time, an unsecured 4 in. rubber hose, which he had inserted in the top of a 5,000 gal tank, jumped out of the tank and sprayed steam and hot water on his lower body. Employee #1 was able to shut off the valve but not before he received serious first- and second-degree burns to 20 percent of his body including the groin, both thighs, lower abdomen, and upper right arm. Employee #1 required hospitalization. The valve was opened to allow steam to mix with cold water to make hot water to put in the 5,000 gal tank.
Keywords: BURN, UNSECURED, WORK RULES, BOILER, THIGH, EQUIPMENT FAILURE, HOSE, STEAM, VALVE, HOT WATER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 111968376 | Hospitalized injury | Burn/Scald(Heat) | Supervisors; handlers,equip-cleaners,laborers nec |