Powered by GoogleTranslate

Inspection Detail

Inspection: 111949731 - Professional Roof Care

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 111949731
Report ID: 0950626
Date Opened: 01/27/1994

Site Address:
Professional Roof Care
4208 South Real Road
Bakersfield, CA 93309

Mailing Address:
2920 Landco Drive, Bakersfield, CA 93308

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/23/1994

Emphasis:

Case Closed: 12/16/1994


Related Activity
Type Activity Nr Safety Health
Accident 362049421
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $3,000 $0 $0 $600 $0 $3,600
Current Penalty $3,000 $0 $0 $600 $0 $3,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 02/24/1994 03/10/1994 $300 $300 $0 -  
2. 01002 Other 1509 A 02/24/1994 03/28/1994 $150 $150 $0 -  
3. 01003 Other 5194 E01 02/24/1994 03/28/1994 $150 $150 $0 -  
4. 02001 Serious 1675 J 02/24/1994 03/10/1994 $3,000 $3,000 $0 -  

Investigation Summary

Investigation Nr: 170703961
Event: 09/28/1993
Employee falls from unsecured ladder

Employee #1 was using a 16-foot extension ladder to climb a roof so that he could show his supervisor some problems with work that had been done earlier. Upon reaching the roof, he started to swing his right leg onto it when he and the ladder fell. Employee #1 sustained a fractured left elbow in the 10-foot free-fall to a concrete surface. The ladder that Employee #1 used was not secured to prevent displacement.

Keywords: FRACTURE, ROOF, UNSECURED, WORK RULES, LADDER, CONSTRUCTION, FALL, ELBOW

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111949731 Hospitalized injury Fracture Roofers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close