Inspection Detail
Inspection: 111948030 - D.M. Camp & Sons
Inspection Information - Office: Fresno District Office
Site Address:
D.M. Camp & Sons
Kratzmeyer & Nord Road
Bakersfield, CA 93312
Mailing Address:
Po Box 80007, Bakersfield, CA 93380
Union Status: NonUnion
SIC:0721
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/04/1993
Emphasis:
Case Closed: 03/31/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361292287 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $185 | $0 | $185 |
| Current Penalty | $0 | $0 | $0 | $185 | $0 | $185 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 B02 | 06/16/1993 | 07/19/1993 | $185 | $185 | $0 | - |
Investigation Summary
An employee was moving an aluminum irrigation pipe in a cotton field. An overhead power line fell and contacted the pipe he was carrying. The employee received an electric shock and electrical burns. He was transported to a hospital, where he died of electrocution.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, AGRICULTURE, ELECTROCUTED, E AG, METAL PIPE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111948030 | Fatality | Electric Shock | Farm workers |
Translate