Inspection Detail
Inspection: 111934428 - J.G. Boswell Gin#2
Inspection Information - Office: Fresno District Office
Site Address:
J.G. Boswell Gin#2
710 Bainum
Corcoran, CA 93212
Mailing Address:
P. O. Box 457, Corcoran, CA 93212
Union Status: NonUnion
SIC:0724
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/28/1991
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 05/29/1991
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361050958 |
Investigation Summary
On October 22, 1990, Employee #1, of the J. G. Boswell Company, was operating a gin when the battery condenser became plugged. To unplug it, he ascended to the top of the battery condenser, opened the top and bottom doors, and then returned to the top door. At this point, he felt air coming up from the machine. Suddenly, the cotton dust inside the condenser erupted in flames, sending a flash of flames to the ceiling and engulfing Employee #1. He suffered first- and second-degree burns on his face, chest, and arms. The cause of the fire remained undetermined at the time this report was written.
Keywords: BURN, CHEST, AGRICULTURE, FIRE, CLOGGED, COTTON GIN, ARM, COMBUSTIBLE DUST, FACE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 111934428 | Hospitalized injury | Burn/Scald(Heat) | Machine operators, not specified |