Powered by GoogleTranslate

Inspection Detail

Inspection: 111914297 - Leslie Hoglund

Inspection Information - Office: Modesto District Office

 

Inspection Nr: 111914297
Report ID: 0950624
Date Opened: 08/28/1990

Site Address:
Leslie Hoglund
565 W. Avenue South
Turlock, CA 95380

Mailing Address:
600 W. Glenwood, Turlock, CA 95380

Union Status: NonUnion

SIC:1796

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/28/1990

Emphasis:

Case Closed: 09/10/1990


Related Activity
Type Activity Nr Safety Health
Accident 361050040
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $1,200 $0 $0 $0 $0 $1,200
Current Penalty $1,200 $0 $0 $0 $0 $1,200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 09/11/1990 08/28/1990 $0 $0 $0 -  
2. 02001 Serious 5420 A02 09/11/1990 08/28/1990 $1,200 $1,200 $0 -  

Investigation Summary

Investigation Nr: 170196505
Event: 07/10/1990
Employee burned when fuel tank ignites

The employer is a dismantler/junk dealer who employs his adult sons on an intermittent basis. Employee #1 has several years experience operating oxygen/propane cutting torches. On July 10, 1990, he cut a drain hole in a large tractor fuel tank that had been partially cut open and was found to be leaking. He noticed additional leakage from the irregular 3 in. by 3 in. opening and, as he moved away, there was an internal flash that spewed flaming vapors and liquid. Employee #1 sustained serious second- and third-degree burns on his face, neck, right side, left arm and hand. No attempt was made to determine the contents of the tank or to safely empty, purge, flush, or inert the tank prior to the cutting activity.

Keywords: BURN, LEAK, ACETYLENE TORCH, FLAMMABLE LIQUID, FLAMMABLE VAPORS, WORK RULES, FIRE, CONSTRUCTION, TANK, CUTTING AND BURNING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111914297 Hospitalized injury Burn/Scald(Heat) Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.