Powered by GoogleTranslate

Inspection Detail

Inspection: 111882403 - Criterion Catalysts Company L.P.

Inspection Information - Office: American Canyon District Office

 

Inspection Nr: 111882403
Report ID: 0950622
Date Opened: 03/06/1991

Site Address:
Criterion Catalysts Company L.P.
2850 Willow Pass Road
Pittsburg, CA 94565

Mailing Address:
, , 00000

Union Status: Union

SIC:2865

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/26/1991

Emphasis:

Case Closed: 02/17/1993


Related Activity
Type Activity Nr Safety Health
Accident 361265077
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 3
Initial Penalty $6,000 $0 $0 $0 $0 $6,000
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 25300086 A01 05/20/1991 06/14/1991 $0 $0 $0 -  
2. 02001 Other 3314 A 05/20/1991 05/22/1991 $0 $2,000 $0 06/03/1991 J - ALJ Decision  
3. 03001 Serious 4184 B 05/20/1991 05/24/1991 $0 $2,000 $0 06/03/1991 J - ALJ Decision Citation has been deleted.
4. 04001 Other 3203 A01 05/20/1991 06/03/1991 $0 $2,000 $0 06/03/1991 J - ALJ Decision  

Investigation Summary

Investigation Nr: 170200489
Event: 02/16/1991
Employee's hand injured when caught by rotating screw

At approximately 8:30 p.m. on February 16, 1991, Employee #1 was using a 1/2 in. diameter by 18 in. long metal rod to unclog a bridge breaker. The bridge breaker was an apparatus installed between the hopper and the extruder to prevent the oil catalyst from hardening and clogging up the process. Since the bridge breaker was not used for all processes, it was not tied into the interlock system. When Employee #1 lifted the grate so that he could better unclog the bridge breaker, he could not see a vertical rotating screw underneath the hardened catalyst. The rod he was using contacted the vertical screw inside the bridge breaker and Employee #1's hand became caught between the screw and the rod. He suffered multiple fractures and lacerations to his hand. Employee #1 was not trained to operate the unit with the bridge breaker installed.

Keywords: FRACTURE, OBSTRUCTED VIEW, WORK RULES, CAUGHT BY, LOCKOUT, CAUGHT BETWEEN, CLOGGED, LACERATION, UNTRAINED, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111882403 Hospitalized injury Cut/Laceration Extruding and forming machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.