Inspection Detail
Inspection: 111865572 - Pml Micro Biologicals
Inspection Information - Office: Sacramento District Office
Site Address:
Pml Micro Biologicals
9881 Horn Rd., Suite F
Sacramento, CA 95827
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2821
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 10/11/1991
Emphasis:
Case Closed: 12/02/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361272289 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A | 10/24/1991 | 11/25/1991 | $0 | $0 | $0 | - | ||
| 2. | 01002 | Other | 3203 B01 | 10/24/1991 | 11/25/1991 | $0 | $0 | $0 | - |
Investigation Summary
While melting a tubular belt, Employee #1 inhaled the polyurethane fumes and suffered the following symptoms: fever, chills, nausea, headache, and shortness of breath. She was hospitalized.
Keywords: RESPIRATORY, HEADACHE, INHALATION, NAUSEA, CHEMICAL VAPOR, TOXIC FUMES
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111865572 | Hospitalized injury | Other | Occupation not reported |
Translate