Powered by GoogleTranslate

Inspection Detail

Inspection: 111845384 - San Juan Asphalt

Inspection Information - Office: Sacramento Mining & Tunneling District Office

 

Inspection Nr: 111845384
Report ID: 0950651
Date Opened: 07/11/1991

Site Address:
San Juan Asphalt
351 Hospital Road
Hollister, CA 95023

Mailing Address:
P. O. Box 490, Goshen, CA 93227

Union Status: Union

SIC:1442

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/11/1991

Emphasis: L:Tunnel

Case Closed: 12/17/1996


Related Activity
Type Activity Nr Safety Health
Accident 361263049
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 4 6
Current Violations 2 4 6
Initial Penalty $3,600 $0 $0 $0 $0 $3,600
Current Penalty $3,600 $0 $0 $0 $0 $3,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1517 A 09/18/1991 09/23/1991 $0 $0 $0 -  
2. 01002 Other 7055 K 09/18/1991 09/23/1991 $0 $0 $0 -  
3. 01003 Other 341 A 09/18/1991 10/18/1991 $0 $0 $0 -  
4. 01004 Other 3203 A02 09/18/1991 09/23/1991 $0 $0 $0 -  
5. 02001 Serious 2946 A 09/18/1991 07/11/1991 $1,800 $1,800 $0 -  
6. 03001 Serious 2946 B03 09/18/1991 07/11/1991 $1,800 $1,800 $0 -  

Investigation Summary

Investigation Nr: 170049712
Event: 07/07/1991
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

A 22-ton mobile crane was being used to move rolls of used conveyor belt from alongside a primary crusher to a site 87 feet away. The destination was directly beneath a 12-kilovolt (phase to ground) overhead power line that was 32 feet above the ground at that point. The employees performing this job took no precautions to avoid contact with the power line. An employee was guiding one of the rolls, which was suspended by a metal chain sling at the end of the crane's load line. The crane's boom contacted the power line, and the employee guiding the load received an electric shock. Electric arcing from the fault ignited the employee's clothing and the grass at his feet. The injured employee was doused with water and rushed to a hospital. He was hospitalized for his injuries.

Keywords: BURN, CLOTHING, ELECTRIC ARC, OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, E GI IA, ELECTRIC SHOCK, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111845384 Hospitalized injury Electric Shock Miscellaneous material moving equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.