Inspection Detail
Inspection: 111842308 - Energy Coatings Co
Inspection Information - Office: American Canyon District Office
Site Address:
Energy Coatings Co
1025 Kaiser Rd.
Napa, CA 94558
Mailing Address:
P.O. Box 3248, Napa, CA 94558
Union Status: NonUnion
SIC:2899
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/20/1991
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 03/13/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361303134 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3328 E | 02/15/1991 | 03/08/1991 | $0 | $0 | $0 | - |
Investigation Summary
On February 14, 1991, Employee #1 and coworkers on the night shift at Energy Coatings Company, were jacking up a 3,300 lb self-propelled rail pipe cart that had been driven into a 2 ft deep pit. They were using an electrical pumping unit connected by a pressure hose to a 30-ton jack. The lifting was done in 2 in. increments, and blocks and shims were used to support the cart when it was not on the jack. The crew had made two or three lifts when the jack operator turned on the pumping unit to again raise the cart. When there was enough clearance to place a shim, Employee #1 told the coworker to stop the pump and he started to put in the shim. When the pump stopped, the jack came down and the cart crushed Employee #1's left thumb. The injury necessitated the amputation of half of Employee #1's thumb. The accident resulted from the design of the pumping unit because the motor is capable of moving more oil than can be passed by the relief valve. Even with the relief valve open, as it was when the accident occurred, the pump could raise the jack, but when the motor was shut off, the jack descended immediately. The relief valve needed to be redesigned.
Keywords: AMPUTATED, SAFETY RELIEF VALVE, THUMB, ELECTRIC PUMP, EQUIPMENT FAILURE, CRUSHED, FALLING OBJECT, JACK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111842308 | Non Hospitalized injury | Amputation | Machinery maintenance occupations |