Inspection Detail
Inspection: 111839858 - James H. Noonan Drywall, Inc.
Inspection Information - Office: American Canyon District Office
Site Address:
James H. Noonan Drywall, Inc.
Cove Ct.
Napa, CA 94559
Mailing Address:
3343 Industrial Drive, #8, Santa Rosa, CA 95403
Union Status: NonUnion
SIC:1742
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/18/1990
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 03/19/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361302532 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 4 | 6 | |||
| Current Violations | 2 | 4 | 6 | |||
| Initial Penalty | $750 | $0 | $0 | $0 | $0 | $750 |
| Current Penalty | $1,250 | $0 | $0 | $0 | $0 | $1,250 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 1646 E | 10/18/1990 | 10/25/1990 | $0 | $0 | $0 | - | ||
| 2. | 01002 | Other | 1646 B | 10/18/1990 | 10/18/1990 | $0 | $0 | $0 | - | ||
| 3. | 01003 | Other | 1509 C | 10/18/1990 | 11/18/1990 | $0 | $0 | $0 | - | ||
| 4. | 01004 | Other | 342 A | 10/18/1990 | 10/18/1990 | $0 | $0 | $0 | - | ||
| 5. | 02001 | Serious | 1646 A | 10/18/1990 | 10/18/1990 | $250 | $250 | $0 | - | ||
| 6. | 03001 | Serious | 1646 B01 | 10/18/1990 | 10/25/1990 | $1,000 | $500 | $0 | 12/03/1990 | J - ALJ Decision |
Investigation Summary
Employee #1 and a coworker were installing sheetrock on the walls and ceiling of a loft, including the 16 ft high ceiling in the living room. They were using an aluminum rolling scaffold with 4 ft extension frames to reach a 10 to 11 ft high by 30 in. wide platform frame. The scaffold was erected parallel to the north wall of the living room, and a long aluminum plank running across the room to the stairway was placed atop the platform. Employee #1 and the coworker were on the scaffold platform placing a ceiling drywall section that did not fit. As they brought down the section from the ceiling, the scaffold tipped over and away from the wall. Employee #1 fell 10 ft off the downhill side and onto the floor; the scaffold landed on top of him. The coworker fell off the uphill side and did not suffer any recordable injuries. The scaffold had no outriggers, nor was it tied or otherwise secured. The upper landing plank was not secured to the floor or to the scaffold platform, and the scaffold's height-to-width measurement exceeded the 3 to 1 maximum allowable ratio.
Keywords: MOBILE SCAFFOLD, UNSECURED, WORK RULES, CONSTRUCTION, FALL, ELEVATED WORK PLAT, TIE-OFF, OVERTURN
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111839858 | Non Hospitalized injury | Fracture | Drywall installers |