Inspection Detail
Inspection: 111837837 - Ray De Mello Construction
Inspection Information - Office: American Canyon District Office
Site Address:
Ray De Mello Construction
1961 Central Ave.
Mckinleyville, CA 95521
Mailing Address:
1245 Spear Ave., Arcata, CA 95521
Union Status: NonUnion
SIC:1542
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/11/1990
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 10/22/1990
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361302615 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 4 | 4 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 1509 B | 10/10/1990 | 10/22/1990 | $0 | $0 | $0 | - | ||
| 2. | 01002 | Other | 1675 K | 10/10/1990 | 10/10/1990 | $0 | $0 | $0 | - | ||
| 3. | 01003 | Other | 1710 B | 10/10/1990 | 10/11/1990 | $0 | $0 | $0 | - | ||
| 4. | 01004 | Other | 1637 A | 10/10/1990 | 10/11/1990 | $0 | $0 | $0 | - |
Investigation Summary
Employees #1 and #2 and two coworkers were setting 60 ft long trusses on the walls of a small, one-story building under construction in a shopping center. Employees #1 and #2 were on the outside walls and the coworkers were in the center, on trusses that had already been set. The truss they were setting broke in the middle and fell to the ground, causing three other trusses and all four workers also to fall to the floor. Employee #1 suffered cracked ribs and Employee #2 cut his arm; the coworkers were unhurt. The employer was cited for a violation of T8CCR 1710(b) for not having an erection procedure, and 1637(a) for not providing a 20 in. wide platform or a scaffold.
Keywords: ERECTION PROCESS, FRACTURE, TRUSS, COLLAPSE, WORK RULES, CONSTRUCTION, RIB, FALL, ELEVATED WORK PLAT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111837837 | Non Hospitalized injury | Fracture | Occupation not reported | ||
| 2 | 111837837 | Non Hospitalized injury | Cut/Laceration | Occupation not reported |