Inspection: 111825568 - Tim Taylor Painting Services

Inspection Information - Office: Oakland District Office

 

Inspection Nr: 111825568
Report ID: 0950614
Date Opened: 01/02/1991

Site Address:
Tim Taylor Painting Services
1134 Bodmin Ave.
San Leandro, CA 94579

Mailing Address:
16633 Cowell St., San Leandro, CA 94578

Union Status: NonUnion

SIC:1721

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/20/1991

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 05/07/1991


Related Activity
Type Activity Nr Safety Health
Accident 361040751
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $1,620 $0 $0 $0 $0 $1,620
Current Penalty $1,620 $0 $0 $0 $0 $1,620
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1510 C 05/07/1991 12/19/1990 $0 $0 $0 -  
2. 02001 Serious 1512 B 05/07/1991 12/19/1990 $1,350 $1,350 $0 -  
3. 03001 Serious 5416 A 05/07/1991 12/19/1990 $135 $135 $0 -  
4. 04001 Serious 1534 B 05/07/1991 12/19/1990 $135 $135 $0 -  

Investigation Summary

Investigation Nr: 170174221
Event: 12/19/1990
One killed, two injured when paint vapor explodes

At approximately 2:30 p.m. on December 19, 1990, Employees #1 through #3 were masking and spray coating in a single-family house. They were using a Dynamite, model D-520 unit, with an ASM mid-400 gun to apply an oil-based primer when there was an explosion and fire. Employee #1 suffered severe burns on his hands and face, and was hospitalized until January 23, 1991. Employee #2 suffered severe burns over 70 percent of his body and died in the hospital on January 17, 1991. Employee #3 suffered a strained back and contusions on his right foot. He was treated at a local hospital and released. The furnace and heater pilot lights were not shut off, and either one could have been a source of ignition.

Keywords: BURN, PILOT LIGHT, FLAMMABLE VAPORS, WORK RULES, FIRE, CONSTRUCTION, SPRAY PAINTING, BACK, EXPLOSION, FOOT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111825568 Hospitalized injury Burn/Scald(Heat) Supervisors; painters, paperhangers and plasterers
2 111825568 Hospitalized injury Burn/Scald(Heat) Supervisors; painters, paperhangers and plasterers
3 111825568 Non Hospitalized injury Burn/Scald(Heat) Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.