Inspection Detail
Inspection: 111825055 - Mid Coast Transportation Inc.
Inspection Information - Office: Oakland District Office
Site Address:
Mid Coast Transportation Inc.
Interstate Hwy 680 & Andrade Rd.
Sunol, CA 94586
Mailing Address:
P.O. Box 74, Alamo, CA 94507
Union Status: NonUnion
SIC:4212
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/02/1990
Emphasis:
Case Closed: 11/20/1990
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361047509 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 2946 A | 11/15/1990 | 08/09/1990 | $0 | $0 | $0 | - |
Investigation Summary
A dump truck driver had stopped his truck beneath a 12-kilovolt overhead power line. He raised the dump truck bed, and it contacted the power line. The employee stepped from the truck cab, unaware of the contact. He was electrocuted.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E GI IA, DUMP TRUCK, DUMP TRUCK BED
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 111825055 | Fatality | Electric Shock | Truck drivers, heavy |