Inspection Detail
Inspection: 111746343 - Stief Company West
Inspection Information - Office: American Canyon District Office
Site Address:
Stief Company West
1075 Blvd. Way
Walnut Creek, CA 94598
Mailing Address:
P. O. Box 800, W. Sacramento, CA 95691
Union Status: Union
SIC:1771
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/29/1993
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 10/12/1999
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362109092 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $2,250 | $0 | $0 | $0 | $0 | $2,250 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 2946 B03 | 05/27/1993 | 04/29/1993 | $0 | $2,250 | $0 | 07/19/1993 | F - Formal Settlement |
Investigation Summary
An employee was delivering concrete forms. He drove a hydraulic truck crane forward at the worksite while the boom was extended 28 feet. The stinger on the boom contacted a 21-kilovolt overhead power line. His foreman yelled for him to back up. The employee drove the truck forward by mistake and severed the power line. The employee was hospitalized for observation.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, E GI IA, CRANE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 111746343 | Hospitalized injury | Other | Industrial truck and tractor equipment operators |