Powered by GoogleTranslate

Inspection Detail

Inspection: 111741740 - Simpson Paper Co.

Inspection Information - Office: American Canyon District Office

 

Inspection Nr: 111741740
Report ID: 0950615
Date Opened: 01/02/1992

Site Address:
Simpson Paper Co.
1900 Bendixon Rd
Fairhaven, CA 95501

Mailing Address:
P. O. Box 4718, Eureka, CA 95501

Union Status: Union

SIC:2611

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/21/1992

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/05/1992


Related Activity
Type Activity Nr Safety Health
Accident 361320567
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A04 B 01/21/1992 01/22/1992 $0 $0 $0 -  
2. 01002 Other 3203 A07 D 01/21/1992 01/22/1992 $0 $0 $0 -  
3. 01003 Other 3383 A 01/21/1992 01/22/1992 $0 $0 $0 -  
4. 01004 Other 3384 A 01/21/1992 01/22/1992 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170170310
Event: 12/20/1991
Utility workers scalded by hot water

Employees #1 and #2, utility workers, were washing down the ash hoppers for a boiler. In the past, cold water had been used. This time, for the first time, Employee #2 was using hot water (75 degrees F) at a higher pressure. While moving the nozzle, he closed the valve. The hose fitting separated at the nozzle and the hose whipped around, spraying hot water. Employee #1, who had been working on the other side using cold water, happened to come around to the side where Employee #2 was working and was sprayed. She sustained burns on 30 percent of her body. Employee #2 was also struck by the scalding water but was not badly injured.

Keywords: BURN, WORK RULES, EQUIPMENT FAILURE, HOSE, LINE CONNECTOR, INEXPERIENCE, HIGH PRESSURE, HOT WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111741740 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 111741740 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close