Powered by GoogleTranslate

Inspection Detail

Inspection: 111600565 - Tacoma Fire Department

Inspection Information - Office: Dosh Tacoma Service Location, Tacoma, Wa

 

Inspection Nr: 111600565
Report ID: 1055330
Date Opened: 11/20/1990

Site Address:
Tacoma Fire Department
On Ship "Gem State" - Schuster Parkway
Tacoma, WA 98402

Mailing Address:
901 Fawcett Ave, Tacoma, WA 98402

Union Status: Union

SIC:9224

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: LocalGovt

Safety/Health: Health

Close Conference: 01/24/1991

Emphasis:

Case Closed: 01/05/2011


Related Activity
Type Activity Nr Safety Health
Referral 900460106 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $9,800 $0 $0 $0 $0 $9,800
Current Penalty $9,800 $0 $0 $0 $0 $9,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 0620710701 02/06/1991 01/24/1991 $3,500 $3,500 $0 02/20/1991 J - ALJ Decision  
2. 01002 Serious 0621450304 02/06/1991 03/10/1991 $2,100 $2,100 $0 02/20/1991 J - ALJ Decision  
3. 01003 Serious 0621450302 02/06/1991 03/10/1991 $2,100 $2,100 $0 02/20/1991 J - ALJ Decision  
4. 01004 Serious 06214523 02/06/1991 01/24/1991 $2,100 $2,100 $0 02/20/1991 J - ALJ Decision  

Investigation Summary

Investigation Nr: 14509657
Event: 11/19/1990
Twenty-seven employees overexposed to carbon monoxide

Employees of Employee/Employer #1 rented a gasoline-powered pump and took it into a tank two decks below the weather deck to pump out some water. The tank was the aft peak tank aboard the vessel Gem State. After 1 1/2 to 2 hours of operation, Employee #2 became dizzy as he climbed the ladder out of the tank and passed out just outside the manhole. He was discovered by Employee #3, who went for help. Employee #3 returned with Employees #4 through #9 after calling 911. Employee #3 sent another employee down to shut off the pump. Fire fighters #10 through #27 arrived on the scene and gave oxygen to Employee #2 and evacuated him. They then began three rescue attempts of Employee #1. Some fire fighters were not wearing any respiratory equipment. No ventilation was provided in the tank and no testing for carbon monoxide was conducted.

Keywords: TOXIC ATMOSPHERE, TOXIC FUMES, PUMP, TANK, CARBON MONOXIDE, VENTILATION, FAINTED, POISONING, WORK RULES, CONFINED SPACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
3 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
4 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
5 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
6 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
7 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
8 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
9 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
10 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
11 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
12 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
13 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
14 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
15 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
16 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
17 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
18 111600565 Hospitalized injury Poisoning(Systemic) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.