Powered by GoogleTranslate

Inspection Detail

Inspection: 111534475 - Ridgeway Plant/James River Corp

Inspection Information - Office: Dosh Seattle Service Location, Seattle, Wa

 

Inspection Nr: 111534475
Report ID: 1055320
Date Opened: 01/11/1991

Site Address:
Ridgeway Plant/James River Corp
4111 156th Ave Ne
Redmond, WA 98073

Mailing Address:
, , 00000

Union Status: Union

SIC:2611

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/18/1991

Emphasis:

Case Closed: 03/26/1991


Related Activity
Type Activity Nr Safety Health
Accident 361198856
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 0242942301 03/08/1991 01/18/1991 $0 $0 $0 -  
2. 01002 Other 0242303505 03/08/1991 01/18/1991 $0 $0 $0 -  
3. 01003 Other 0249560706 D 03/08/1991 01/18/1991 $0 $0 $0 -  
4. 01004 Other 0242351302 B 03/08/1991 03/17/1991 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170047963
Event: 01/11/1991
ELECTRIC SHOCK - GROUND FAULT IN ELECTRICAL BOX

An employee was moving a microswitch counter for a Miehle cutting press (Model No. 51). The press was stopped, and he had his left hand under the switch. When he put his right hand on top of the switch, he received an electric shock. He withdrew his hands in reaction to the shock and cut his right forearm and hand on a sharp stripping pin on the edge of the upper stripping board on the machine. The employee started shaking and appeared to be suffering from shock. He was hospitalized overnight for his injuries. An electrician disassembled and examined the microswitch. The electrician found that the end of the black, ungrounded circuit conductor was missing insulation to about 6 millimeters from the terminal. No defects were noted in the white, neutral conductor. The green, equipment grounding conductor had been cut off, leaving the microswitch and box ungrounded.

Keywords: ELECTRICAL, ELECTRIC SWITCH, E GI VII, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC SHOCK, ELECTRICAL BOX, CONTUSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111534475 Hospitalized injury Cut/Laceration Miscellaneous machine operators, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.