Inspection Detail
Inspection: 111534475 - Ridgeway Plant/James River Corp
Inspection Information - Office: Dosh Seattle Service Location, Seattle, Wa
Site Address:
Ridgeway Plant/James River Corp
4111 156th Ave Ne
Redmond, WA 98073
Mailing Address:
, , 00000
Union Status: Union
SIC:2611
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/18/1991
Emphasis:
Case Closed: 03/26/1991
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361198856 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 4 | ||||
Current Violations | 4 | 4 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 0242942301 | 03/08/1991 | 01/18/1991 | $0 | $0 | $0 | - | ||
2. | 01002 | Other | 0242303505 | 03/08/1991 | 01/18/1991 | $0 | $0 | $0 | - | ||
3. | 01003 | Other | 0249560706 D | 03/08/1991 | 01/18/1991 | $0 | $0 | $0 | - | ||
4. | 01004 | Other | 0242351302 B | 03/08/1991 | 03/17/1991 | $0 | $0 | $0 | - |
Investigation Summary
An employee was moving a microswitch counter for a Miehle cutting press (Model No. 51). The press was stopped, and he had his left hand under the switch. When he put his right hand on top of the switch, he received an electric shock. He withdrew his hands in reaction to the shock and cut his right forearm and hand on a sharp stripping pin on the edge of the upper stripping board on the machine. The employee started shaking and appeared to be suffering from shock. He was hospitalized overnight for his injuries. An electrician disassembled and examined the microswitch. The electrician found that the end of the black, ungrounded circuit conductor was missing insulation to about 6 millimeters from the terminal. No defects were noted in the white, neutral conductor. The green, equipment grounding conductor had been cut off, leaving the microswitch and box ungrounded.
Keywords: ELECTRICAL, ELECTRIC SWITCH, E GI VII, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC SHOCK, ELECTRICAL BOX, CONTUSION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 111534475 | Hospitalized injury | Cut/Laceration | Miscellaneous machine operators, n.e.c. |