Inspection Detail
Inspection: 111443297 - Takata Moses Lake Inc
Inspection Information - Office: Dosh Yakima Service Location, Yakima, Wa
Site Address:
Takata Moses Lake Inc
On Site 311 Slugger Press
Moses Lake, WA 98837
Mailing Address:
9255 Randolph Rd Ne, Moses Lake, WA 98837
Union Status: NonUnion
SIC:3599
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/08/1993
Emphasis:
Case Closed: 08/13/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361226467 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $375 | $0 | $0 | $0 | $0 | $375 |
| Current Penalty | $375 | $0 | $0 | $0 | $0 | $375 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 0241800505 | 07/16/1993 | 06/08/1993 | $375 | $375 | $0 | - |
Investigation Summary
Employee #2 was setting up equipment to dress a grinding stone in preparation for a machining operation. The 2 3/4 inch pulley was installed on the motor and the 7/8 inch pulley was installed on the spindle, the reverse of proper installation. With the motor turning at 10,000 rpm, this incorrect setup caused the stone to turn at approximately 30,000 rpm. Consequently, the grinding wheel blew up. A guard was not installed on the grinding stone and Employees #1 and #2 were hit with shrapnel.
Keywords: WORK RULES, FLYING OBJECT, GRINDING MACHINE, UNGUARDED, INATTENTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111443297 | Hospitalized injury | Cut/Laceration | Occupation not reported |
Translate