Inspection Detail
Inspection: 111402210 - Gutter King
Inspection Information - Office: Dosh Seattle Service Location, Seattle, Wa
Site Address:
Gutter King
18935 104th Ave Ne
Bothell, WA 98011
Mailing Address:
5012 Picnic Point Rd, Edmonds, WA 98020
Union Status: NonUnion
SIC:1761
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/24/1991
Emphasis: L:Constr
Case Closed: 11/16/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361198344 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 3 | 5 | |||
| Current Violations | 2 | 3 | 5 | |||
| Initial Penalty | $1,440 | $0 | $0 | $0 | $0 | $1,440 |
| Current Penalty | $1,080 | $0 | $0 | $0 | $0 | $1,080 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 1550042801 D 01 | 05/16/1991 | 04/24/1991 | $900 | $1,200 | $0 | 06/07/1991 | J - ALJ Decision | |
| 2. | 01002A | Serious | 1550048001 O | 05/16/1991 | 04/24/1991 | $240 | $240 | $0 | 06/07/1991 | J - ALJ Decision | Citation has been deleted. |
| 3. | 01002B | Serious | 1550048001 N | 05/16/1991 | 04/24/1991 | $0 | $0 | $0 | 06/07/1991 | J - ALJ Decision | Citation has been deleted. |
| 4. | 01002C | Serious | 1550048001 W | 05/16/1991 | 04/24/1991 | $180 | $0 | $0 | 06/07/1991 | J - ALJ Decision | |
| 5. | 01002D | Serious | 1550048001 J | 05/16/1991 | 04/24/1991 | $0 | $0 | $0 | 06/07/1991 | J - ALJ Decision | |
| 6. | 02001 | Other | 1550012001 | 05/16/1991 | 07/17/1991 | $0 | $0 | $0 | 06/07/1991 | J - ALJ Decision | |
| 7. | 02002 | Other | 1550011001 | 05/16/1991 | 03/06/1992 | $0 | $0 | $0 | 06/07/1991 | J - ALJ Decision | |
| 8. | 02003 | Other | 1552450501 | 05/16/1991 | 03/06/1992 | $0 | $0 | $0 | 06/07/1991 | J - ALJ Decision |
Investigation Summary
Two employees of a gutter installation company were handling rain gutters at a worksite. A gutter contacted a 7200-volt overhead power line, and both employees received electric shocks. One of them fell 8.2 meters to the ground. The employees were hospitalized for their injuries.
Keywords: RAIN SPOUT, OVERHEAD POWER LINE, ELECTRICAL, ELECTRIC SHOCK, FALL, E GI IC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111402210 | Hospitalized injury | Electric Shock | Construction trades, n.e.c. | ||
| 2 | 111402210 | Hospitalized injury | Electric Shock | Construction trades, n.e.c. |