Powered by GoogleTranslate

Inspection Detail

Inspection: 111345021 - Guy F Atkinson Construction Co

Inspection Information - Office: Dosh Spokane Service Location, Spokane, Wa

 

Inspection Nr: 111345021
Report ID: 1055360
Date Opened: 06/18/1992

Site Address:
Guy F Atkinson Construction Co
Northbound On Ramp From 169 To 405
Renton, WA 98055

Mailing Address:
Po Box 1158, Mercer Island, WA 98040

Union Status: Union

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/09/1992

Emphasis: L:Euc

Case Closed: 12/23/1992


Related Activity
Type Activity Nr Safety Health
Accident 361193402
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $1,300 $0 $0 $0 $0 $1,300
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 1550042801 D 01 09/03/1992 07/09/1992 $1,300 $1,300 $0 09/23/1992 Y - State Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 170238075
Event: 06/18/1992
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

An employee had rigged a load of rebar to be unloaded at a worksite by a truck-mounted boom. The employee climbed off the trailer and placed a small load of rebar on his right shoulder and started to walk around the trailer. The boom operator then positioned the load near its destination. To get the load as close as possible to the worksite, the operator lowered the boom and slacked off the winch line. The boom contacted a 7200-volt overhead power line just as the first employee touched the trailer with his left hand. The employee received an electric shock. He was hospitalized for his injuries.

Keywords: BOOM TRUCK, OVERHEAD POWER LINE, ELECTRICAL, BOOM, E C, ELECTRIC SHOCK, TRUCK BOOM

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111345021 Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.