Inspection Detail
Inspection: 111294047 - Columbia Aluminum Corp
Inspection Information - Office: Dosh Tumwater Service Location, Tumwater, Wa
Site Address:
Columbia Aluminum Corp
85 John Day Dam Rd
Goldendale, WA 98620
Mailing Address:
, , 00000
Union Status: Union
SIC:3322
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 03/12/1992
Emphasis:
Case Closed: 06/29/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361193899 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $3,750 | $0 | $0 | $0 | $0 | $3,750 |
| Current Penalty | $3,750 | $0 | $0 | $0 | $0 | $3,750 |
| FTA Penalty | $10,000 | $0 | $0 | $3,000 | $0 | $13,000 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 0620311201 | 04/16/1992 | 05/19/1992 | $3,750 | $3,750 | $10,000 | J - ALJ Decision | ||
| 2. | 01001B | Serious | 0620311203 D | 04/16/1992 | 05/19/1992 | $0 | $0 | $0 | J - ALJ Decision | ||
| 3. | 01001C | Serious | 0620711501 B 02 | 04/16/1992 | 05/19/1992 | $0 | $0 | $0 | J - ALJ Decision | ||
| 4. | 01001D | Serious | 0620311205 | 04/16/1992 | 05/19/1992 | $0 | $0 | $0 | J - ALJ Decision | ||
| 5. | 02001 | Other | 0240007304 B | 04/16/1992 | 06/18/1992 | $0 | $0 | $3,000 | J - ALJ Decision | ||
| 6. | 02002 | Other | 0620710901 | 04/16/1992 | 05/19/1992 | $0 | $0 | $0 | - |
Investigation Summary
At approximately 5:00 p.m. on October 29, 1991, the cast house day crew used the #10 pendulum crane to suspend a rotor over the #5 casting furnace sniff box for pre-heating before insertion into the sniff box. At 5:00 p.m., the relief crew. including Employees #1, #5, and #7, completed a drop in DC #1. While Employees #1 and #5 took a break, Employee #7 made a drop in DC #2. When Employees #1 and #5 returned, Employee #5 attempted to move the #10 pendulum crane from the east end of the furnace to the west end to pull logs at DC #1. The crane alarms were used. When the crane moved west 18 in., the rotor snagged sniff box #5's overhead gas lines, causing several pipes, including a chlorine gas line, to rupture. The employees were overexposed to chlorine gas in a number of situations: attempting to repair the damage without donning SCBA; removing the SCBA when they thought they were in clear air; bringing extra SCBA into the contaminated zone; continuing the job in the contaminated area because it was critical; or being unaware of the chlorine gas cloud. Employee #1 escaped through the west exit ramp when he smelled the chlorine gas, but returned through the same route with a boxed SCBA for Employee #3, the mechanic. Employee #1 held his breath as he approached #5CF. When he was out of air, he inhaled on the east side of #5CF, but the air flow was west to east and he was in a gas cloud. Employee #1 was hospitalized. Not wearing SCBA or any type of respirator, Employee #2 , the foreman, attempted to disconnect the gas hoses to the damaged rotor air base of #5CF, but suffered overexposure before he could complete the task. Employee #3, a mechanic, was called to the scene. His SCBA ran out while he was on top of #5CF so he went to the east side of the operations floor near an opened SCBA box. Employee #3 lifted the mask, but suffered overexposure. Employee #7 continued to monitor the drop in DC #2 by filling his lungs at the south door and running to the furnace area while holding his breath. Employee #7 made four to five trips before Employee #4, who was wearing SCBA, arrived to watch. Completing the job was critical because of an explosion hazard. Employee #6 was working east of the cast house, which is an area within a larger building, and saw the commotion. She did not stop her task until escaping employees told her to leave. No chlorine monitoring equipment or alarm system was available.
Keywords: WORK RULES, ALARM, GAS, RUPTURE, CHLORINE, SCBA, AIR CONTAMINATION, RESPIRATOR
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111294047 | Non Hospitalized injury | Other | Occupation not reported | ||
| 2 | 111294047 | Hospitalized injury | Other | Occupation not reported | ||
| 3 | 111294047 | Non Hospitalized injury | Other | Occupation not reported | ||
| 4 | 111294047 | Non Hospitalized injury | Other | Occupation not reported | ||
| 5 | 111294047 | Non Hospitalized injury | Other | Occupation not reported | ||
| 6 | 111294047 | Non Hospitalized injury | Other | Occupation not reported | ||
| 7 | 111294047 | Non Hospitalized injury | Other | Occupation not reported |