Inspection: 111167854 - Prestige Plastering
Inspection Information - Office: Nv-E-Las Vegas 0953220
Site Address:
Prestige Plastering
844 E. Sahara Ave.
Las Vegas, NV 89104
Mailing Address:
5375 S. Cameron, #A, Las Vegas, NV 89118
Union Status: NonUnion
SIC:1742
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/30/1990
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 09/18/1996
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360765119 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $1,620 | $10,000 | $0 | $0 | $0 | $11,620 |
| Current Penalty | $1,620 | $10,000 | $0 | $0 | $0 | $11,620 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Willful | 19260416 A01 | 09/26/1990 | 09/10/1990 | $10,000 | $10,000 | $0 | 09/26/1990 | L - State Settlement | |
| 2. | 02001A | Serious | 19260021 B02 | 09/26/1990 | 09/14/1990 | $1,620 | $1,620 | $0 | 09/26/1990 | L - State Settlement | |
| 3. | 02001B | Serious | 19260451 A13 | 09/26/1990 | 09/14/1990 | $0 | $0 | $0 | 09/26/1990 | L - State Settlement | |
| 4. | 02001C | Serious | 19260451 D10 | 09/26/1990 | 09/14/1990 | $0 | $0 | $0 | 09/26/1990 | L - State Settlement |
Investigation Summary
An employee was climbing a scaffold that had been erected 300 millimeters from a 7200-volt overhead power line. The employee tried to squeeze between the top guardrail of the scaffold and the power line. He contacted the power line with the back of his neck and received an electric shock. The employee fell 6 meters, struck a block wall, and fell 2 more meters to the ground. The employee was hospitalized for his injuries. The employer had erected the scaffold too close to the power lines even after employees had voiced their concerns.
Keywords: E GI III, OVERHEAD POWER LINE, ELECTRICAL, ELECTRIC SHOCK, FALL, SCAFFOLD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111167854 | Hospitalized injury | Electric Shock | Plasterers |