Inspection Detail
Inspection: 111138038 - Skatemor Ice House, Inc.
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Skatemor Ice House, Inc.
1410 Buck Jones Road
Raleigh, NC 27606
Mailing Address:
P. O. Box 4243, Cary, NC 27519
Union Status: Union
SIC:7999
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 07/28/1992
Emphasis:
Case Closed: 02/24/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360490908 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $900 | $0 | $0 | $0 | $0 | $900 |
| Current Penalty | $900 | $0 | $0 | $0 | $0 | $900 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19101000 A03 | 12/22/1992 | 12/30/1992 | $900 | $900 | $0 | - | ||
| 2. | 02001 | Other | 19100037 K02 | 12/22/1992 | 12/30/1992 | $0 | $0 | $0 | - | ||
| 3. | 02002 | Serious | 19100305 G01 III | 12/22/1992 | 12/30/1992 | $0 | $0 | $0 | - |
Investigation Summary
At 12:45 p.m. on July 14, 1992, the Skatemor Ice House was evacuated due to buildup of carbon monoxide from a propane-powered Zamboni ice resurfacer. The Raleigh Hazardous Materials Team measured 208 ppm of carbon monoxide and 480 ppm carbon monoxide after operating the Zamboni for 4 minutes. Of the 90 children who were at the rink attending a Raleigh Youth Hockey Association Camp, 55 children reported headaches, 30 were nauseated, and 6 were transported to the hospital. Employees #1 and #2 were transported to the Western Wake Medical Center, but were not admitted. Poor ventilation of the ice rink and inadequate maintenance of the Zamboni (tuning the machine to keep carbon monoxide emissions as low as possible) were major factors contributing to the poisoning.
Keywords: VENTILATION, EMERGENCY RESPONSE, INADEQUATE MAINT, HEADACHE, NAUSEA, OVEREXPOSURE, CARBON MONOXIDE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111138038 | Non Hospitalized injury | Asphyxia | Automobile mechanic apprentices | ||
| 2 | 111138038 | Non Hospitalized injury | Asphyxia | Food counter, fountain and related occupations |