Inspection Detail
Inspection: 111137329 - Huron Tech Corp.
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Huron Tech Corp.
John L. Riegel Rd.
Riegelwood, NC 28546
Mailing Address:
P. O. Box 189, Delco, NC 28436
Union Status: NonUnion
SIC:2819
NAICS: 0
Inspection Type: Planned
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 11/06/1992
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 10/04/1993
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $375 | $0 | $0 | $0 | $0 | $375 |
| Current Penalty | $375 | $0 | $0 | $0 | $0 | $375 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 95012901 | 12/11/1992 | 04/13/1993 | $375 | $375 | $0 | 01/05/1993 | F - Formal Settlement |
Investigation Summary
At approximately 7:45 a.m. on June 12, 1992, a leak was discovered at the brine exit flange on the #24 sodium chlorate electrolytic cell. The cell line was shut down at 8:01 a.m. At this time, a purge cycle to remove toxic/flammable gases from the header system was initiated. This included 15 CFM of nitrogen for 15 minutes, a 30 minute rest period, and an additional 15 CFM of nitrogen for 15 minutes. Employees thought that the first purge was successful due to the audible purging sound and the readings of the rotameters on the nitrogen line. An explosion occurred at 8:49 a.m., about the time the second purge was to begin. Employee #1 was walking through the area as a short-cut. Employee #2 was at the base of the #24 cell and was hit by flying objects. Employees #3 and #4 were on the catwalk near the #24 and #26 cells, respectively. The four employees sustained various injuries, but were not hospitalized.
Keywords: HYDROGEN, EXPLOSION, STRUCK BY, FLYING OBJECT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 111137329 | Non Hospitalized injury | Cut/Laceration | Occupation not reported | ||
| 2 | 111137329 | Non Hospitalized injury | Puncture | Occupation not reported | ||
| 3 | 111137329 | Non Hospitalized injury | Puncture | Occupation not reported |