Inspection: 111110862 - Arj, Inc.

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 111110862
Report ID: 0453710
Date Opened: 10/07/1994

Site Address:
Arj, Inc.
Route 1
Albertson, NC 28508

Mailing Address:
1007 North 4th St., Wilmington, NC 28401

Union Status: NonUnion

SIC:1742

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/17/1994

Emphasis:

Case Closed: 09/12/1997


Related Activity
Type Activity Nr Safety Health
Accident 360493704
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $11,200 $0 $0 $0 $0 $11,200
Current Penalty $7,840 $0 $0 $0 $0 $7,840
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260416 A03 01/05/1995 01/11/1995 $1,960 $2,800 $0 I - Informal Settlement  
2. 01002 Serious 19260416 G02 IB 01/05/1995 01/11/1995 $2,940 $4,200 $0 I - Informal Settlement  
3. 01003 Serious 19260021 B02 01/05/1995 01/11/1995 $2,940 $4,200 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 170060040
Event: 10/06/1994
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU SCAFFOLD

Three employees were moving a 7.90-meter-tall Rustgo Model 195 mobile work platform across a construction site. They were pushing the platform manually because none of them had a hitch installed on his vehicle. Two of the employees were pushing, and the other was pulling the platform and using its tongue to steer. Because they could not get the scaffold over a curb, they decided to bring it out of the main entrance to the construction site, travel 91 meters north along a highway, and reenter the site by a service road. A 13-kilovolt overhead power line located 7.87 meters above the ground ran parallel to the highway. As the scaffold reached the highway at the main entrance, the back of the platform contacted the power line. The two employees pushing the scaffold received electric shocks and were thrown clear. The other employee received an electric shock and collapsed with his left arm in contact with the scaffold tongue for about 2 to 3 minutes, until the line separated at the point of contact. He was electrocuted. The two injured employees were hospitalized for electric shock and for burns to their hands and feet.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, MOBILE SCAFFOLD, ELECTROCUTED, E C, ELECTRIC SHOCK, SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111110862 Fatality Electric Shock Supervisors, n.e.c.
2 111110862 Hospitalized injury Electric Shock Construction laborers
3 111110862 Hospitalized injury Electric Shock Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.