Inspection Detail
Inspection: 111109831 - Blanton Service Co.
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Blanton Service Co.
1219 Dawson Street
Wilmington, NC 28401
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:1711
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/31/1994
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 08/31/1994
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360493472 |
Investigation Summary
An employee was installing heating ducts in a crawl space in a house. When he drilled a hole in a floor joist, the drill contacted a two-conductor electric cable. This cable was punctured by edge of the strap he was installing to support the duct. The aluminum strap pierced the insulation on one of the conductors, energizing the strap and the drill. The employee was electrocuted. A coworker was called to assist the injured employee. When the coworker touched the injured employee, who was still in contact with the energized drill, the coworker was also electrocuted. The owner of the house opened the main disconnect for the house's wiring and called for emergency services. Emergency medical services responded and started cardio-pulmonary resuscitation to no avail. Both employees were pronounced dead at a hospital 1 hour and 10 minutes after the accident.
Keywords: ELEC INSULATION, ELECTRICAL, SHEET METAL, E GI VI, ELECTRIC CABLE, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC DRILL, CRAWL SPACE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 111109831 | Fatality | Electric Shock | Helpers, construction trades | ||
2 | 111109831 | Fatality | Electric Shock | Heating, air conditioning, and refrig. mechanics |