Powered by GoogleTranslate

Inspection Detail

Inspection: 110619574 - Dept Of Interior, Bureau Of Land Management

Inspection Information - Office: San Francisco Ro

 

Inspection Nr: 110619574
Report ID: 0935000
Date Opened: 08/27/1996

Site Address:
Dept Of Interior, Bureau Of Land Management
1101 Beverly
Carson City, NV 89701

Mailing Address:
1535 Hot Springs Road, Suite 300, Carson City, NV 89701

Union Status: NonUnion

SIC:9512

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership:  

Safety/Health: Safety

Close Conference: 08/30/1996

Emphasis:

Case Closed: 05/28/1997


Related Activity
Type Activity Nr Safety Health
Accident 360939003
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 8 4 12
Current Violations 8 4 12
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100134 B08 12/13/1996 12/18/1996 $0 $0 $0 -  
2. 01002 Serious 19100134 B10 12/13/1996 12/18/1996 $0 $0 $0 -  
3. 01003 Serious 19100146 C01 12/13/1996 12/18/1996 $0 $0 $0 -  
4. 01004 Serious 19100243 C01 12/13/1996 12/18/1996 $0 $0 $0 -  
5. 01005 Serious 19100252 B04 IV 12/13/1996 12/18/1996 $0 $0 $0 -  
6. 01006 Serious 19100252 C02 II 12/13/1996 12/18/1996 $0 $0 $0 -  
7. 01007 Serious 19100252 C04 I 12/13/1996 12/18/1996 $0 $0 $0 -  
8. 01008A Serious 19101200 H 12/13/1996 01/15/1997 $0 $0 $0 -  
9. 01008B Serious 19101200 H01 I 12/13/1996 12/18/1996 $0 $0 $0 -  
10. 02001 Other 19600011 12/13/1996 01/15/1997 $0 $0 $0 -  
11. 02002 Other 19600055 A 12/13/1996 01/15/1997 $0 $0 $0 -  
12. 02003 Other 19600012 B 12/13/1996 01/15/1997 $0 $0 $0 -  
13. 02004 Other 19101200 E04 12/13/1996 01/15/1997 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 876094
Event: 08/25/1996
Employee dies while welding tank

Employee #1 was a member of a water tank (tanker) crew and a fire fighter for the Bureau of Land Management. While he was on duty, the fire tank of his truck developed a leak in the rear bulkhead area. He consulted with his supervisor, who decided that the employee would repair the leaks. This required him to enter the water truck's tank, grind off paint, and weld (mig) the cracks. During the first phase of the job, Employee #1 passed out for a few seconds, revived, went to lunch, and returned to the tank. After about eight minutes of grinding and welding, he passed out again and never regained consciousness. He was pronounced dead approximately two hours later at the hospital.

Keywords: UNCONSCIOUSNESS, CONFINED SPACE, WORK RULES, WELDING, TANK, WATER TANK, RESPIRATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 110619574 Fatality Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close